User:Melissa Novy/Notebook/CHEM-581/2012/10/03
From OpenWetWare
< User:Melissa Novy | Notebook | CHEM-581 | 2012 | 10(Difference between revisions)
(Autocreate 2012/10/03 Entry for User:Melissa_Novy/Notebook/CHEM-581) |
Current revision (12:22, 22 October 2012) (view source) (→Objectives) |
||
| (6 intermediate revisions not shown.) | |||
| Line 14: | Line 14: | ||
|colspan="2"| | |colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
| - | == | + | ==Objectives== |
| - | * | + | * Crosslink Na-MT films. |
| + | ** Please refer to [[User:Moira_M._Esson/Notebook/CHEM-581/2012/10/03|Moira Esson's entry]] for all calculations and observations. | ||
| + | ** The following films were crosslinked: PVOH (MW 22000), 0.8 wt% glutaraldehyde, 0.1 wt% 100% CEC NaMT; PVOH (MW 22000), 0.8 wt% glutaraldehyde, 0.1 wt% NaMT; PVOH (MW 22000), 0.8 wt% glutaraldehyde, PDMS. | ||
| + | * Adjust the pH of CuSO<sub>4</sub> solutions made on [[User:Melissa_Novy/Notebook/CHEM-581/2012/09/28|2012/09/28]], then take ISE measurements. | ||
| + | ==CuSO<sub>4</sub> Standard, Na<sup>+</sup> Standard, and Na-MT Filtrate Solutions== | ||
| + | * Please refer to the ISE protocol on [[User:Melissa_Novy/Notebook/CHEM-581/2012/09/28|2012/09/28]] for how ISE measurements were taken. | ||
| + | ** 3 mL of the solutions were added to 0.1 mL of ionic strength adjuster (4 M solution containing NaOH) to adjust the pH to a value between 8 and 10. | ||
| + | ** The solutions were allowed to equilibrate with the electrode for 2 min. | ||
| + | * Dilutions of 5 mL each of 1, 5, 10, 15, and 20 ppm Na<sup>+</sup> in pure H<sub>2</sub>O were made from a 1000 ppm Na<sup>+</sup> solution, then ISE measurements were taken. | ||
| + | * Calculations | ||
| + | '''5 mL 20 ppm Na<sup>+</sup> requires:''' | ||
| + | '''(1000 ppm Na<sup>+</sup>)V<sub>1</sub>=(20 ppm Na<sup>+</sup>)(5 mL)''' | ||
| + | '''V<sub>1</sub>=100 μL''' | ||
| + | <br> | ||
| + | '''5 mL 10 ppm Na<sup>+</sup> requires:''' | ||
| + | '''(1000 ppm Na<sup>+</sup>)V<sub>1</sub>=(10 ppm Na<sup>+</sup>)(5 mL)''' | ||
| + | '''V<sub>1</sub>=50 μL''' | ||
| + | <br> | ||
| + | '''5 mL 5 ppm Na<sup>+</sup> requires:''' | ||
| + | '''(1000 ppm Na<sup>+</sup>)V<sub>1</sub>=(5 ppm Na<sup>+</sup>)(5 mL)''' | ||
| + | '''V<sub>1</sub>=25 μL''' | ||
| + | <br> | ||
| + | '''5 mL 5 ppm Na<sup>+</sup> requires:''' | ||
| + | '''(1000 ppm Na<sup>+</sup>)V<sub>1</sub>=(5 ppm Na<sup>+</sup>)(5 mL)''' | ||
| + | '''V<sub>1</sub>=25 μL''' | ||
| + | <br> | ||
| + | '''5 mL 1 ppm Na<sup>+</sup> requires:''' | ||
| + | '''(1000 ppm Na<sup>+</sup>)V<sub>1</sub>=(1 ppm Na<sup>+</sup>)(5 mL)''' | ||
| + | '''V<sub>1</sub>=5 μL''' | ||
| + | <br> | ||
| + | CuSO<sub>4</sub> Standard Solutions | ||
| + | {| {{table}} | ||
| + | | align="center" style="background:#f0f0f0;"|'''Concentration [ppm]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''pH''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''ISE [mV]''' | ||
| + | |- | ||
| + | | 1||9.52||-215.5 | ||
| + | |- | ||
| + | | 2||9.48||-207.5 | ||
| + | |- | ||
| + | | 5||9.47||-207.9 | ||
| + | |- | ||
| + | | 10||9.43||-211.7 | ||
| + | |- | ||
| + | | 15||9.45||-151.1 | ||
| + | |} | ||
| + | <br> | ||
| + | [[Image:CuSO4_ISE_Standards.JPG]] | ||
| + | <br><br> | ||
| + | Na<sup>+</sup> Standard Solutions | ||
| + | {| {{table}} | ||
| + | | align="center" style="background:#f0f0f0;"|'''Concentration [ppm]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''ISE [mV]''' | ||
| + | |- | ||
| + | | 1||-147 | ||
| + | |- | ||
| + | | 5||-158 | ||
| + | |- | ||
| + | | 10||-145.5 | ||
| + | |- | ||
| + | | 20||-132.3 | ||
| + | |} | ||
| + | <br> | ||
| + | 100% CEC (Na-MT)-CuSO<sub>4</sub> Filtrate | ||
| + | {| {{table}} | ||
| + | | align="center" style="background:#f0f0f0;"|'''Cu<sup>+2</sup> Concentration [ppm]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''Time [min]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''pH''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''ISE [mV]''' | ||
| + | |- | ||
| + | | 7.4||1||9.53||-201.2 | ||
| + | |- | ||
| + | | 10||1||8.47||-174.1 | ||
| + | |- | ||
| + | | 7.4||5||9.52||-200.5 | ||
| + | |- | ||
| + | | 10||5||8.45||-172.5 | ||
| + | |- | ||
| + | | 7.4||10||8.51||-172.3 | ||
| + | |- | ||
| + | | 10||10||9.53||-199 | ||
| + | |} | ||
| + | <br> | ||
| + | 50% CEC (Na-MT)-CuSO<sub>4</sub> Filtrate | ||
| + | {| {{table}} | ||
| + | | align="center" style="background:#f0f0f0;"|'''Cu<sup>+2</sup> Concentration [ppm]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''Time [min]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''ISE [mV]''' | ||
| + | |- | ||
| + | | 7.4||1||-172.7 | ||
| + | |- | ||
| + | | 10||1||-171.4 | ||
| + | |- | ||
| + | | 7.4||5||-174.8 | ||
| + | |- | ||
| + | | 10||5||-174.2 | ||
| + | |- | ||
| + | | 7.4||10||-168.9 | ||
| + | |- | ||
| + | | 10||10||-172.8 | ||
| + | |} | ||
| + | <br> | ||
| + | Unmodified (Na-MT)-CuSO<sub>4</sub> Filtrate | ||
| + | {| {{table}} | ||
| + | | align="center" style="background:#f0f0f0;"|'''Cu<sup>+2</sup> Concentration [ppm]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''Time [min]''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''pH''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''ISE [mV]''' | ||
| + | |- | ||
| + | | 7.4||1||8.37||-128.2 | ||
| + | |- | ||
| + | | 10||1||8.45||-142.1 | ||
| + | |- | ||
| + | | 7.4||5||8.47||-112.7 | ||
| + | |- | ||
| + | | 10||5||8.5||-99.2 | ||
| + | |- | ||
| + | | 7.4||10||8.44||-138 | ||
| + | |- | ||
| + | | 10||10||8.44||-134.5 | ||
| + | |} | ||
| + | |||
| + | ==Notes== | ||
| + | * The 1 ppm Na<sup>+</sup> solution gave an ISE value that did not fit the expected calibration curve. This may be because the detection limit of the ISE measurements is above 1 ppm. It was recommended that a solution of higher Na<sup>+</sup> ppm, such as 25 ppm Na<sup>+</sup> be tested to generate a more accurate calibration curve. | ||
| + | * The ISE values of the CuSO<sub>4</sub> solutions are meaningless as they were obtained with a sodium electrode. | ||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | ||
| - | |||
__NOTOC__ | __NOTOC__ | ||
Current revision
Customize your entry pages
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Objectives
CuSO4 Standard, Na+ Standard, and Na-MT Filtrate Solutions
5 mL 20 ppm Na+ requires: (1000 ppm Na+)V1=(20 ppm Na+)(5 mL) V1=100 μL
5 mL 10 ppm Na+ requires: (1000 ppm Na+)V1=(10 ppm Na+)(5 mL) V1=50 μL
5 mL 5 ppm Na+ requires: (1000 ppm Na+)V1=(5 ppm Na+)(5 mL) V1=25 μL
5 mL 5 ppm Na+ requires: (1000 ppm Na+)V1=(5 ppm Na+)(5 mL) V1=25 μL
5 mL 1 ppm Na+ requires: (1000 ppm Na+)V1=(1 ppm Na+)(5 mL) V1=5 μL
Notes
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||