User:Melvin Colorado Escobar/Notebook/582/2015/03/18: Difference between revisions
From OpenWetWare
(Autocreate 2015/03/18 Entry for User:Melvin_Colorado_Escobar/Notebook/582) |
(fix raw html notebook nav) |
||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
{|{{table}} width="800" | {|{{table}} width="800" | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image: | |style="background-color: #EEE"|[[Image:BDLlogo_notext_lr.png|128px]]<span style="font-size:22px;"> Biomaterials Design Lab</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
== | |||
* | |||
==Objective== | |||
100mg of AuNP was not enough to show detection in EIS, therefore we will be testing metal dusts to gauge an estimate as to how much is needed to be detected. | |||
==Description== | |||
*We made a solution around 6.25% which is approximately 0.1g | |||
*For 15% (15.25%), 0.27g needed | |||
*For 20% (21%), 0.4g needed | |||
*For 25%, 0.5g needed | |||
*For 30% (30.2%), 0.65g needed | |||
We will be working with Copper because it is the most conductive metal dust we have. | |||
==Data== | |||
{| {{table}} | |||
| align="center" style="background:#f0f0f0;"|'''15% Cu''' | |||
| align="center" style="background:#f0f0f0;"|'''20% Cu''' | |||
| align="center" style="background:#f0f0f0;"|'''25% Cu''' | |||
| align="center" style="background:#f0f0f0;"|'''30% Cu''' | |||
|- | |||
| 1.44083g PEO||1.44065g PEO||1.44099g PEO||1.44532g PEO | |||
|- | |||
| 0.06274g Trifilate||0.06153g Trifilate||0.06176g Trifilate||0.06072g Trifilate | |||
|- | |||
| 0.272292g Cu||0.39989g Cu||0.50776g Cu||0.65705g Cu | |||
|} | |||
==Notes== | |||
This area is for any observations or conclusions that you would like to note. | |||
Use categories like tags. Change the "Course" category to the one corresponding to your course. The "Miscellaneous" tag can be used for particular experiments, as instructed by your professor. Please be sure to change or delete this tag as required so that the categories remain well organized. | |||
[[Category:Course]] | |||
[[Category:Miscellaneous]] | |||
[[Category:Course]] | |||
[[Category:Miscellaneous]] | |||
Line 14: | Line 57: | ||
__NOTOC__ | __NOTOC__ | ||
Latest revision as of 00:56, 27 September 2017
Biomaterials Design Lab | Main project page Previous entry Next entry | ||||||||||||||||
Objective100mg of AuNP was not enough to show detection in EIS, therefore we will be testing metal dusts to gauge an estimate as to how much is needed to be detected. Description
We will be working with Copper because it is the most conductive metal dust we have. Data
NotesThis area is for any observations or conclusions that you would like to note.
|