Objective

  • To make standardized curves for determining peptide concentration using fluorescence analysis.

Description

  • Dr. Hartings left a procedure for us to use today in his lab notebook.
  • We are using the Pierce quantitative fluorometric peptide assay. (product link here)
  1. Perform a protease digest of lysozyme
    1. Make a stock lysozyme solution (~ 1mg/mL) using phosphate buffer
    2. Make your protease stock by adding 1mL to your pre-measured protease
    3. Make a sample that has a final volume of 1mL and protease concentration of 1uM
      1. Add the appropriate volume of protease sample to a clean eppendorf tube
      2. Add a volume of lysozyme solution so that the final volume is 1mL
    4. Make a blank sample (no lysozyme)
      1. Add the appropriate volume of protease sample to a clean eppendorf tube
      2. Add a volume of buffer solution so that the final volume is 1mL
    5. Add both tubes to the 37C water bath for 1hr
    6. Make standards for analysis
      1. Standard A: 150uL of reaction sample
      2. Standard B: 75uL of Standard A and 75uL of water
      3. Standard C: 75uL of Standard B and 75uL of water
      4. Standard D: 75uL of Standard C and 75uL of water
      5. Standard E: 75uL of Standard D and 75uL of water
      6. Standard F: 75uL of Standard E and 75uL of water
      7. Standard G: 75uL of Standard F and 75uL of water
      8. Standard H: 75uL of Standard G and 75uL of water
    7. Make blanks for analysis
      1. Blank A: 150uL of blank sample
      2. Blank B: 75uL of Blank A and 75uL of water
      3. Blank C: 75uL of Blank B and 75uL of water
      4. Blank D: 75uL of Blank C and 75uL of water
      5. Blank E: 75uL of Blank D and 75uL of water
      6. Blank F: 75uL of Blank E and 75uL of water
      7. Blank G: 75uL of Blank F and 75uL of water
      8. Blank H: 75uL of Blank G and 75uL of water
  2. Make Samples for Measurement
    1. For each of the standards and blanks described above mix the following
      1. 20uL of sample
      2. 140uL of Assay Buffer
      3. 40uL of Assay Reagent
  3. Take Measurement
    1. Excitation at 390 nm
    2. Emission from 400 to 650 nm

Data

  • Add data and results here...

Notes

This area is for any observations or conclusions that you would like to note.


Use categories like tags. Change the "Course" category to the one corresponding to your course. The "Miscellaneous" tag can be used for particular experiments, as instructed by your professor. Please be sure to change or delete this tag as required so that the categories remain well organized.