==Description==
[[Image:Autoclave222.jpg]]
*Tattnauer Brinkman 3545M
*Tabletop autoclave
 
 
==Use==
*Twist dial on bottom right corner to "Fill" and wait for water to fill up to the metal ridge near the door.
*Insert the material that needs to be autoclaved.
*Close the door and twist the door handle shut.
*Set temperature and time
*Turn knob to "sterilize"
*Wait 30 minutes after sterilization is complete for pressure to reach 0psi,  before openning autoclave.
 
==Safety==
*After autoclaving, wait until pressure dial is at 0psi before opening the autoclave. This takes about 30 minutes.
 
==Specifications==
*12.2" wide, 18.5" deep
*3.25L refillable water reservoir
*corrosion resistant chamber
*exhaust options
 





Revision as of 21:41, 7 December 2012

Project name <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
This page is a template and should not be edited.
Click F. Nagle/Notebook/Tattnauer Brinkman 3545M/2012/12/07&action=edit here, copy the source, and paste it into your page.


Description

  • Tattnauer Brinkman 3545M
  • Tabletop autoclave


Use

  • Twist dial on bottom right corner to "Fill" and wait for water to fill up to the metal ridge near the door.
  • Insert the material that needs to be autoclaved.
  • Close the door and twist the door handle shut.
  • Set temperature and time
  • Turn knob to "sterilize"
  • Wait 30 minutes after sterilization is complete for pressure to reach 0psi, before openning autoclave.

Safety

  • After autoclaving, wait until pressure dial is at 0psi before opening the autoclave. This takes about 30 minutes.

Specifications

  • 12.2" wide, 18.5" deep
  • 3.25L refillable water reservoir
  • corrosion resistant chamber
  • exhaust options