User:Michael S. Bible/Notebook/571/2014/09/09: Difference between revisions
No edit summary |
|||
Line 35: | Line 35: | ||
[[Image:Fluorometer_Readings_on_L-Tryptophan_chart.png]] | [[Image:Fluorometer_Readings_on_L-Tryptophan_chart.png]] | ||
==New Kinetics Experiment== | |||
The experiment that was performed on August 27th was repeated using 20 minute intervals between measurements. The same general [[User:Michael_S._Bible/Notebook/571/2014/08/27|procedure]] was followed except that 5 tubes of solution were prepared so that there would be enough to perform 10 measurements over 3 hours. The results of that experiment can be found below. | |||
==Results of Kinetics Experiment== | |||
Our lysozyme-gold solution, as before, took far longer to show signs of AuNP formation than did the solutions of other groups performing the same experiment. For example, see [[User:Paul_Rothenberg/Notebook/CHEM_571_Fall_2014/2014/09/09|Paul's results]] for the same experiment. | |||
See a graph below of the kinetics run for AuNP-formation at 70°C, sampled at 20 minute intervals below: | |||
[[Image:Kinetics_of_AuNP_Formation_in_Lysozyme.png]] | |||
[[Category:Course]] | [[Category:Course]] |
Revision as of 20:58, 18 September 2014
Biomaterials Design Lab | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
ObjectiveToday we took UV/Vis spectra of the amino acid solutions made on 9/3. Description
UV-Vis Absorbance Curves for Amino AcidsFluorometryBelow is a graph of the data acquired from fluorometry on 81.2 nM L-Tryptophan. A wavelength of 275 nm was used to excite the solution. The small molarity is the result of a 2500:1 dilution of a 203 μM solution of L-Tryptophan. Tryptophan was the only one of our 5 amino acids that produced any significant results in UV-Vis and was, therefore, the only amino acid that was tested using Fluorometry. New Kinetics ExperimentThe experiment that was performed on August 27th was repeated using 20 minute intervals between measurements. The same general procedure was followed except that 5 tubes of solution were prepared so that there would be enough to perform 10 measurements over 3 hours. The results of that experiment can be found below. Results of Kinetics ExperimentOur lysozyme-gold solution, as before, took far longer to show signs of AuNP formation than did the solutions of other groups performing the same experiment. For example, see Paul's results for the same experiment. See a graph below of the kinetics run for AuNP-formation at 70°C, sampled at 20 minute intervals below:
|