Figure 4 shows the calculations done to determine the concentration of Lysozyme in each solution.  From these calculations, it would seem that the actual concentration of stock Lysozyme solution is .005 g/L rather than .5 g/L as believed.
Figure 4 shows the calculations done to determine the concentration of Lysozyme in each solution.  From these calculations, it would seem that the actual concentration of stock Lysozyme solution is .0056 g/L rather than .5 g/L as believed.





Revision as of 12:55, 19 October 2014

Biomaterials Design Lab <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>



Analysis of Dialysis Begun Yesterday

Post-dialysis solutions from all of the wells in the dialysis chamber were analyzed using UV-Vis using the following protocol:

  • Remove 20 μL of solution from each chamber (10 in all) and run Bradford analysis
    • Bradford reagent should be diluted 1:3 with 50mM Tris/50mM NaCl
    • Recall, 20 μL solution + 200 μL diluted Bradford + 780 μL Tris/NaCl buffer
    • PS cuvettes, measuring 400 - 800 nm
    • Don't forget to run a blank with just Bradford & buffer
    • Don't forget to run your undialyzed Lysozyme stock

Procedure taken from Dr. Fox


Data

Figure 1 shows the corrected UV-Vis Bradford Spectra for all Post-Dialysis Solutions.

Figure 2 shows the corrected UV-Vis Bradford Spectra for the post-dialysis solutions from the non-protein side of the dialysis chamber. From the negative absorbance values, it is clear that there is no protein present. This is expected since the dialysis tubing used had a molecular weight cut-off of 3500 g/mol.

Figure 3 shows the corrected UV-Vis Bradford Spectra for the post-dialysis solutions from the protein side of the dialysis chamber. It is clear from the spectra that there is still a lot of protein in each of the chambers, and the post-dialysis concentration of Lysozyme in solution almost perfectly matches the concentration of Lysozyme in the stock solution.

Figure 4 shows the calculations done to determine the concentration of Lysozyme in each solution. From these calculations, it would seem that the actual concentration of stock Lysozyme solution is .0056 g/L rather than .5 g/L as believed.