User:Moira M. Esson/Notebook/CHEM-581/2012/10/10
From OpenWetWare
< User:Moira M. Esson | Notebook | CHEM-581 | 2012 | 10(Difference between revisions)
(→Entry title) |
Current revision (10:01, 16 October 2012) (view source) (→Atomic Absorption) |
||
| (6 intermediate revisions not shown.) | |||
| Line 6: | Line 6: | ||
| colspan="2"| | | colspan="2"| | ||
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit above this line unless you know what you are doing. ##### --> | ||
| - | == | + | ==Objectives== |
| + | #Prepare samples for DSC | ||
| + | #Run clay exchange described on [[User:Moira_M._Esson/Notebook/CHEM-581/2012/09/26|2012/09/26]] using Fe<sub>3</sub>O<sub>4</sub> | ||
| + | #Rerun AA for CuSO<sub>4</sub> solutions | ||
| + | |||
| + | ==DSC== | ||
| + | Samples were prepared following the general protocol for DSC preparation described on [[User:Moira_M._Esson/Notebook/CHEM-581/2012/09/07|2012/9/07]] | ||
| + | <br> | ||
| + | '''DSC Sample Preparation''' | ||
| + | {| {{table}} | ||
| + | | align="center" style="background:#f0f0f0;"|'''Sample Name''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''Pan+lid mass(g)''' | ||
| + | | align="center" style="background:#f0f0f0;"|'''Mass sample(g)''' | ||
| + | |- | ||
| + | | PVOH 130,000+[H3PO4]+15%maleic acid||0.04939||0.00281 | ||
| + | |- | ||
| + | | PVOH 130,000||0.0495||0.00283 | ||
| + | |- | ||
| + | | PVOH 22,000+[HCl]||0.04933|| | ||
| + | |} | ||
| + | *'''Note''':DSC did not have the attached gas and was unable to be used. Prepared samples will be run and the data will be collected when next in the labaratory | ||
| + | |||
| + | ==Atomic Absorption== | ||
| + | *Solutions run were prepared on [[User:Moira_M._Esson/Notebook/CHEM-581/2012/09/21|2012/09/21]] | ||
| + | *The General Protocol for AA described on [[User:Moira_M._Esson/Notebook/CHEM-581/2012/10/05|2012/10/05]] was used | ||
| + | <br> | ||
| + | '''Atomic Absorption Data from AA wizard''': | ||
| + | |||
{| {{table}} | {| {{table}} | ||
| align="center" style="background:#f0f0f0;"|'''Cu''' | | align="center" style="background:#f0f0f0;"|'''Cu''' | ||
| Line 82: | Line 109: | ||
| UNK24||10ppm CEC 50% 10min||||15.0057||0.6102 | | UNK24||10ppm CEC 50% 10min||||15.0057||0.6102 | ||
|} | |} | ||
| + | <br> | ||
| + | '''Calibration Curve''' | ||
| + | '''General Notes''': | ||
| + | *The standards used were too high of a concentration. Need to remake CuSO<sub>4</sub> standards between 5-20ppm. | ||
| + | *All Fe<sub>3</sub>O<sub>4</sub> samples need to be reprepared and retested. Solutions were prepared with CuSO<sub>4</sub> instead of deionized H<sub>2</sub>O. Concentrations were inaccurate and calibration curve created was inaccurate | ||
| + | *AA needs to be run again | ||
<!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | <!-- ##### DO NOT edit below this line unless you know what you are doing. ##### --> | ||
Current revision
Main project page Previous entry Next entry
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Objectives
DSCSamples were prepared following the general protocol for DSC preparation described on 2012/9/07
Atomic Absorption
General Notes:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||