User:Moira M. Esson/Notebook/CHEM-581/2012/11/05: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(fix raw html notebook nav)
 
(One intermediate revision by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 43: Line 43:
#PVOH(22K)+1mL GA+50% CEC crosslinked prepared 10/4/2012
#PVOH(22K)+1mL GA+50% CEC crosslinked prepared 10/4/2012
#PVOH(22K)+0.5mL GA+NaMT crosslinked prepared 10/19/2012
#PVOH(22K)+0.5mL GA+NaMT crosslinked prepared 10/19/2012
==UV-vis==
==UV-vis==
*The general protocol for UV-vis was followed
*The general protocol for UV-vis was followed

Latest revision as of 22:11, 26 September 2017

Project name Main project page
Previous entry      Next entry

Objectives

  1. Run FTIR on crosslinked glutaraldehyde films dried and weighed on 10/2/12
  2. Weigh and dry more crosslinked glutaraldehyde films in preparations for running FTIR
  3. Run DSC on crosslinked glutaraldehyde films dried and weighed on 10/2/12
  4. Finish running UV-vis on porphyrine solutions

FTIR

  • The general protocol for preparing crosslinked glutaraldehyde films for FTIR described on 2012/11/02 was followed

Prepared films:

Films New mass(g)
PVOH(22K) 1.0067g+1mL GA+1mL porphyrin crosslinked 1.7688
PVOH(22K)+0.5mL GA+0.104g NaMT crosslinked spun 10 min CuSO4 prepared 10/17/2012 0.9465
PVOH(22K)+0.5mLGA+0.99mL porphyrin(no color on film )crosslinked prepared 10/19/2012 1.8045
PVOH(22K)+1mL GA+100%CEC crosslinked prepared 10/4/2012 1.3662
PVOH(22K)+1mL GA+1mL porphyrin crosslinked prepared 10/24/2012 1.5477
PVOH(22K)+0.5mL GA+1mL porphyrin crosslinked prepared 10/24/2012 #2 1.9685
PVOH(22K)+0.5mLGA+1mL porphyrin prepared crosslinked 10/26/2012 2.1206
PVOH(22K)+0.8wt% GA+100%CEC crosslinked spun 10 min CuSO4 prepared 10/26/2012 1.24
PVOH(22K)+0.8wt% GA+50% CEC crosslinked spun 10 min CuSO4 prepared 10/17/2012 1.074


Films:

  1. PVOH(22K)+0.5mL GA+100% CEC crosslinked prepared 10/19/2012
  2. PVOH(22K)+0.8wt% GA+100%CEC crosslinked prepared 10/3/2012
  3. PVOH(22K)+1mL GA+50% CEC crosslinked prepared 10/4/2012
  4. PVOH(22K)+0.5mL GA+NaMT crosslinked prepared 10/19/2012

UV-vis

  • The general protocol for UV-vis was followed

Samples ran UV-vis on:

  1. PVOH(22K) 1.0067g+1mL GA+1mL porphyrin fixant solution from crosslinking
  2. PVOH(22K)+0.5mL GA+1mL porphyrin prepared 10/26/2012 fixant solution from crosslinking
  3. PVOH(22K)+1.0mL GA+1mL porphyrin prepared 10/24/2012 fixant solution from crosslinking
  4. PVOH(22K) 1.05225g+0.5mL GA+1mL porphyrin prepared 10/26/2012 fixant solution from crosslinking


Notes:

  • All obtained spectra will be uploaded
  • Baseline was run with an empty quartz cuvette
  • Blank was run with HPLC grade H2O
  • At first the samples were run under the kinetics option of the Shimadzu UV-2550 spectrophotometer. Must remember to change the option