User:Moira M. Esson/Notebook/CHEM-581/2013/02/27

From OpenWetWare

(Difference between revisions)
Jump to: navigation, search
(Pressure tests)
(Pressure tests)
Line 55: Line 55:
<br>
<br>
Figure 1. Image of bent pipette used for pressure testing
Figure 1. Image of bent pipette used for pressure testing
 +
<br>
[[Image:Bent pipette 2 27 13.jpg]]
[[Image:Bent pipette 2 27 13.jpg]]
<br>
<br>
Line 62: Line 63:
<br>
<br>
Figure 3. Fluorescence of all Lamponite hydrogel samples
Figure 3. Fluorescence of all Lamponite hydrogel samples
 +
<br>
 +
[[Image:Fluorescence of Rhodamine 6G collected after pressure testing(bent pipette) on hydrogels with Lamponite clay.png]]
Figure 4. Fluorescence of all hydrogel samples
Figure 4. Fluorescence of all hydrogel samples
<br>
<br>

Revision as of 23:09, 7 March 2013

Project name Main project page
Previous entry      Next entry

Objectives

  1. Perform pressure tests on all prepared hydrogels using a bent pipette.
  2. Run fluorescence on the samples obtained from the pressure tests.


Pressure tests

  • Pressure tests were performed on all hydrogels prepared with Rhodamine 6G added.
  • After the sheer pressure test conducted on 2013/02/22, it was determined that a bent pipette and an unmodified pipette would be used to conduct the pressure tests. Each hydrogel will have at least two pressure tests conducted with the hydrogel: one with a bent pipette and the other with an unmodified pipette.
  • All pressure tests were conducted following the general protocol described on 2013/02/22.


Table 1. Pressure testing information for hydrogels using a bent pipette

Sample Order PVOH vs. Clay Ratio PVOH Type Clay Selection Amount of Hydrogel Used (g)
190:10146K110% CEC NaMT w/ DMHXLBR0.1084
290:10130KNaMT0.1044
350:50146K110% CEC NaMT0.1092
490:10130K110% CEC Laponite0.1050
550:50130KNaMT0.1050
690:10130KLaponite0.1015
750:50146K110% CEC Laponite0.1080
850:50130KLaponite0.1036
990:10130K110% CEC NaMT0.1011
1050:50130K110% CEC Laponite0.1036
1190:10130K110% CEC NaMT0.1011
1290:10146KLaponite0.1026
1350:50130K50% CEC NaMT Bu3HdP+0.1052
1450:50146KLaponite0.1045
1590:10130K50% CEC NaMT Bu3HdP+0.1145


Figure 1. Image of bent pipette used for pressure testing
Image:Bent pipette 2 27 13.jpg
Figure 2. Fluorescence of all NaMT hydrogel ssmples
Image:Fluorescence of Rhodamine 6G obtained from pressure tests of NaMT clay containing hydrogels using a bent pipette.png
Figure 3. Fluorescence of all Lamponite hydrogel samples
Image:Fluorescence of Rhodamine 6G collected after pressure testing(bent pipette) on hydrogels with Lamponite clay.png Figure 4. Fluorescence of all hydrogel samples
Image:Bent pipette pressure testing.png

  • Correction: The x-axis should be labeled wavelength(nm). The image will be corrected.



Personal tools