User:Moira M. Esson/Notebook/CHEM-581/2013/02/27

From OpenWetWare

< User:Moira M. Esson | Notebook | CHEM-581 | 2013 | 02(Difference between revisions)
Jump to: navigation, search
(Pressure tests)
Current revision (00:10, 8 March 2013) (view source)
(Pressure tests)
 
(8 intermediate revisions not shown.)
Line 14: Line 14:
*After the sheer pressure test conducted on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]], it was determined that a bent pipette and an unmodified pipette would be used to conduct the pressure tests. Each hydrogel will have at least two pressure tests conducted with the hydrogel: one with a bent pipette and the other with an unmodified pipette.
*After the sheer pressure test conducted on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]], it was determined that a bent pipette and an unmodified pipette would be used to conduct the pressure tests. Each hydrogel will have at least two pressure tests conducted with the hydrogel: one with a bent pipette and the other with an unmodified pipette.
*All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]].
*All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]].
-
,br>
 
-
Table
 
<br>
<br>
-
Figure 1. Image of bent pipette used for pressure testing
+
'''Table 1. Pressure testing information for hydrogels using a bent pipette'''
-
    
+
{| {{table}}
 +
| align="center" style="background:#f0f0f0;"|'''Sample Order'''
 +
| align="center" style="background:#f0f0f0;"|'''PVOH vs. Clay Ratio'''
 +
| align="center" style="background:#f0f0f0;"|'''PVOH Type'''
 +
| align="center" style="background:#f0f0f0;"|'''Clay Selection'''
 +
| align="center" style="background:#f0f0f0;"|'''Amount of Hydrogel Used (g)'''
 +
|-
 +
| 1||90:10||146K||110% CEC NaMT w/ DMHXLBR||0.1084
 +
|-
 +
| 2||90:10||130K||NaMT||0.1044
 +
|-
 +
| 3||50:50||146K||110% CEC NaMT||0.1092
 +
|-
 +
| 4||90:10||130K||110% CEC Laponite||0.1050
 +
|-
 +
| 5||50:50||130K||NaMT||0.1050
 +
|-
 +
| 6||90:10||130K||Laponite||0.1015
 +
|-
 +
| 7||50:50||146K||110% CEC Laponite||0.1080
 +
|-
 +
| 8||50:50||130K||Laponite||0.1036
 +
|-
 +
| 9||90:10||130K||110% CEC NaMT||0.1011
 +
|-
 +
| 10||50:50||130K||110% CEC Laponite||0.1036
 +
|-
 +
| 11||90:10||130K||110% CEC NaMT||0.1011
 +
|-
 +
| 12||90:10||146K||Laponite||0.1026
 +
|-
 +
| 13||50:50||130K||50% CEC NaMT Bu<sub>3</sub>HdP<sup>+</sup>||0.1052
 +
|-
 +
| 14||50:50||146K||Laponite||0.1045
 +
|-
 +
| 15||90:10||130K||50% CEC NaMT Bu<sub>3</sub>HdP<sup>+</sup>||0.1145
 +
|}
 +
<br>
 +
  '''Figure 1. Image of bent pipette used for pressure testing'''
 +
<br>
 +
[[Image:Bent pipette 2 27 13.jpg]]
 +
<br>
 +
   '''Figure 2. Fluorescence of all NaMT hydrogel ssmples'''
 +
<br>
 +
[[Image:Fluorescence of Rhodamine 6G obtained from pressure tests of NaMT clay containing hydrogels using a bent pipette.png]]
 +
<br>
 +
  '''Figure 3. Fluorescence of all Lamponite hydrogel samples'''
 +
<br>
 +
[[Image:Fluorescence of Rhodamine 6G collected after pressure testing(bent pipette) on hydrogels with Lamponite clay.png]]
 +
  '''Figure 4. Fluorescence of all hydrogel samples'''
 +
<br>
 +
[[Image:Bent pipette pressure testing.png]]
 +
<br>
 +
*'''Correction''': The x-axis should be labeled wavelength(nm). The image will be corrected.
 +
 

Current revision

Project name Main project page
Previous entry      Next entry

Objectives

  1. Perform pressure tests on all prepared hydrogels using a bent pipette.
  2. Run fluorescence on the samples obtained from the pressure tests.


Pressure tests

  • Pressure tests were performed on all hydrogels prepared with Rhodamine 6G added.
  • After the sheer pressure test conducted on 2013/02/22, it was determined that a bent pipette and an unmodified pipette would be used to conduct the pressure tests. Each hydrogel will have at least two pressure tests conducted with the hydrogel: one with a bent pipette and the other with an unmodified pipette.
  • All pressure tests were conducted following the general protocol described on 2013/02/22.


Table 1. Pressure testing information for hydrogels using a bent pipette

Sample Order PVOH vs. Clay Ratio PVOH Type Clay Selection Amount of Hydrogel Used (g)
190:10146K110% CEC NaMT w/ DMHXLBR0.1084
290:10130KNaMT0.1044
350:50146K110% CEC NaMT0.1092
490:10130K110% CEC Laponite0.1050
550:50130KNaMT0.1050
690:10130KLaponite0.1015
750:50146K110% CEC Laponite0.1080
850:50130KLaponite0.1036
990:10130K110% CEC NaMT0.1011
1050:50130K110% CEC Laponite0.1036
1190:10130K110% CEC NaMT0.1011
1290:10146KLaponite0.1026
1350:50130K50% CEC NaMT Bu3HdP+0.1052
1450:50146KLaponite0.1045
1590:10130K50% CEC NaMT Bu3HdP+0.1145


 Figure 1. Image of bent pipette used for pressure testing


Image:Bent pipette 2 27 13.jpg

 Figure 2. Fluorescence of all NaMT hydrogel ssmples


Image:Fluorescence of Rhodamine 6G obtained from pressure tests of NaMT clay containing hydrogels using a bent pipette.png

 Figure 3. Fluorescence of all Lamponite hydrogel samples


Image:Fluorescence of Rhodamine 6G collected after pressure testing(bent pipette) on hydrogels with Lamponite clay.png

 Figure 4. Fluorescence of all hydrogel samples


Image:Bent pipette pressure testing.png

  • Correction: The x-axis should be labeled wavelength(nm). The image will be corrected.