User:Moira M. Esson/Notebook/CHEM-581/2013/02/27: Difference between revisions
From OpenWetWare
(7 intermediate revisions by the same user not shown) | |||
Line 15: | Line 15: | ||
*All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]]. | *All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]]. | ||
<br> | <br> | ||
Table | '''Table 1. Pressure testing information for hydrogels using a bent pipette''' | ||
{| {{table}} | |||
| align="center" style="background:#f0f0f0;"|'''Sample Order''' | |||
| align="center" style="background:#f0f0f0;"|'''PVOH vs. Clay Ratio''' | |||
| align="center" style="background:#f0f0f0;"|'''PVOH Type''' | |||
| align="center" style="background:#f0f0f0;"|'''Clay Selection''' | |||
| align="center" style="background:#f0f0f0;"|'''Amount of Hydrogel Used (g)''' | |||
|- | |||
| 1||90:10||146K||110% CEC NaMT w/ DMHXLBR||0.1084 | |||
|- | |||
| 2||90:10||130K||NaMT||0.1044 | |||
|- | |||
| 3||50:50||146K||110% CEC NaMT||0.1092 | |||
|- | |||
| 4||90:10||130K||110% CEC Laponite||0.1050 | |||
|- | |||
| 5||50:50||130K||NaMT||0.1050 | |||
|- | |||
| 6||90:10||130K||Laponite||0.1015 | |||
|- | |||
| 7||50:50||146K||110% CEC Laponite||0.1080 | |||
|- | |||
| 8||50:50||130K||Laponite||0.1036 | |||
|- | |||
| 9||90:10||130K||110% CEC NaMT||0.1011 | |||
|- | |||
| 10||50:50||130K||110% CEC Laponite||0.1036 | |||
|- | |||
| 11||90:10||130K||110% CEC NaMT||0.1011 | |||
|- | |||
| 12||90:10||146K||Laponite||0.1026 | |||
|- | |||
| 13||50:50||130K||50% CEC NaMT Bu<sub>3</sub>HdP<sup>+</sup>||0.1052 | |||
|- | |||
| 14||50:50||146K||Laponite||0.1045 | |||
|- | |||
| 15||90:10||130K||50% CEC NaMT Bu<sub>3</sub>HdP<sup>+</sup>||0.1145 | |||
|} | |||
<br> | |||
'''Figure 1. Image of bent pipette used for pressure testing''' | |||
<br> | <br> | ||
[[Image:Bent pipette 2 27 13.jpg]] | [[Image:Bent pipette 2 27 13.jpg]] | ||
<br> | |||
'''Figure 2. Fluorescence of all NaMT hydrogel ssmples''' | |||
<br> | |||
[[Image:Fluorescence of Rhodamine 6G obtained from pressure tests of NaMT clay containing hydrogels using a bent pipette.png]] | |||
<br> | |||
'''Figure 3. Fluorescence of all Lamponite hydrogel samples''' | |||
<br> | |||
[[Image:Fluorescence of Rhodamine 6G collected after pressure testing(bent pipette) on hydrogels with Lamponite clay.png]] | |||
'''Figure 4. Fluorescence of all hydrogel samples''' | |||
<br> | |||
[[Image:Bent pipette pressure testing.png]] | |||
<br> | |||
*'''Correction''': The x-axis should be labeled wavelength(nm). The image will be corrected. | |||
Revision as of 21:10, 7 March 2013
Project name | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Objectives
Pressure tests
Figure 1. Image of bent pipette used for pressure testing Figure 2. Fluorescence of all NaMT hydrogel ssmples Figure 3. Fluorescence of all Lamponite hydrogel samples Figure 4. Fluorescence of all hydrogel samples
|