User:Moira M. Esson/Notebook/CHEM-581/2013/02/27: Difference between revisions
From OpenWetWare
(fix raw html notebook nav) |
|||
(9 intermediate revisions by one other user not shown) | |||
Line 2: | Line 2: | ||
|- | |- | ||
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | |style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span> | ||
|style="background-color: #F2F2F2" align="center"| | |style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 14: | Line 14: | ||
*After the sheer pressure test conducted on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]], it was determined that a bent pipette and an unmodified pipette would be used to conduct the pressure tests. Each hydrogel will have at least two pressure tests conducted with the hydrogel: one with a bent pipette and the other with an unmodified pipette. | *After the sheer pressure test conducted on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]], it was determined that a bent pipette and an unmodified pipette would be used to conduct the pressure tests. Each hydrogel will have at least two pressure tests conducted with the hydrogel: one with a bent pipette and the other with an unmodified pipette. | ||
*All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]]. | *All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]]. | ||
<br> | <br> | ||
Figure 1. Image of bent pipette used for pressure testing | '''Table 1. Pressure testing information for hydrogels using a bent pipette''' | ||
{| {{table}} | |||
| align="center" style="background:#f0f0f0;"|'''Sample Order''' | |||
| align="center" style="background:#f0f0f0;"|'''PVOH vs. Clay Ratio''' | |||
| align="center" style="background:#f0f0f0;"|'''PVOH Type''' | |||
| align="center" style="background:#f0f0f0;"|'''Clay Selection''' | |||
| align="center" style="background:#f0f0f0;"|'''Amount of Hydrogel Used (g)''' | |||
|- | |||
| 1||90:10||146K||110% CEC NaMT w/ DMHXLBR||0.1084 | |||
|- | |||
| 2||90:10||130K||NaMT||0.1044 | |||
|- | |||
| 3||50:50||146K||110% CEC NaMT||0.1092 | |||
|- | |||
| 4||90:10||130K||110% CEC Laponite||0.1050 | |||
|- | |||
| 5||50:50||130K||NaMT||0.1050 | |||
|- | |||
| 6||90:10||130K||Laponite||0.1015 | |||
|- | |||
| 7||50:50||146K||110% CEC Laponite||0.1080 | |||
|- | |||
| 8||50:50||130K||Laponite||0.1036 | |||
|- | |||
| 9||90:10||130K||110% CEC NaMT||0.1011 | |||
|- | |||
| 10||50:50||130K||110% CEC Laponite||0.1036 | |||
|- | |||
| 11||90:10||130K||110% CEC NaMT||0.1011 | |||
|- | |||
| 12||90:10||146K||Laponite||0.1026 | |||
|- | |||
| 13||50:50||130K||50% CEC NaMT Bu<sub>3</sub>HdP<sup>+</sup>||0.1052 | |||
|- | |||
| 14||50:50||146K||Laponite||0.1045 | |||
|- | |||
| 15||90:10||130K||50% CEC NaMT Bu<sub>3</sub>HdP<sup>+</sup>||0.1145 | |||
|} | |||
<br> | |||
'''Figure 1. Image of bent pipette used for pressure testing''' | |||
<br> | |||
[[Image:Bent pipette 2 27 13.jpg]] | |||
<br> | |||
'''Figure 2. Fluorescence of all NaMT hydrogel ssmples''' | |||
<br> | |||
[[Image:Fluorescence of Rhodamine 6G obtained from pressure tests of NaMT clay containing hydrogels using a bent pipette.png]] | |||
<br> | |||
'''Figure 3. Fluorescence of all Lamponite hydrogel samples''' | |||
<br> | |||
[[Image:Fluorescence of Rhodamine 6G collected after pressure testing(bent pipette) on hydrogels with Lamponite clay.png]] | |||
'''Figure 4. Fluorescence of all hydrogel samples''' | |||
<br> | |||
[[Image:Bent pipette pressure testing.png]] | |||
<br> | |||
*'''Correction''': The x-axis should be labeled wavelength(nm). The image will be corrected. | |||
Latest revision as of 22:30, 26 September 2017
Project name | Main project page Previous entry Next entry | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Objectives
Pressure tests
Figure 1. Image of bent pipette used for pressure testing Figure 2. Fluorescence of all NaMT hydrogel ssmples Figure 3. Fluorescence of all Lamponite hydrogel samples Figure 4. Fluorescence of all hydrogel samples
|