User:Moira M. Esson/Notebook/CHEM-581/2013/02/27: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(fix raw html notebook nav)
 
(2 intermediate revisions by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 15: Line 15:
*All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]].
*All pressure tests were conducted following the general protocol described on [[User:Moira_M._Esson/Notebook/CHEM-581/2013/02/22|2013/02/22]].
<br>
<br>
Table 1. Pressure testing information for hydrogels using a bent pipette
'''Table 1. Pressure testing information for hydrogels using a bent pipette'''
{| {{table}}
{| {{table}}
| align="center" style="background:#f0f0f0;"|'''Sample Order'''
| align="center" style="background:#f0f0f0;"|'''Sample Order'''
Line 54: Line 54:
|}
|}
<br>
<br>
Figure 1. Image of bent pipette used for pressure testing
  '''Figure 1. Image of bent pipette used for pressure testing'''
<br>
[[Image:Bent pipette 2 27 13.jpg]]
[[Image:Bent pipette 2 27 13.jpg]]
<br>
<br>
Figure 2. Fluorescence of all NaMT hydrogel ssmples
  '''Figure 2. Fluorescence of all NaMT hydrogel ssmples'''
<br>
<br>
[[Image:Fluorescence of Rhodamine 6G obtained from pressure tests of NaMT clay containing hydrogels using a bent pipette.png]]
[[Image:Fluorescence of Rhodamine 6G obtained from pressure tests of NaMT clay containing hydrogels using a bent pipette.png]]
<br>
<br>
Figure 3. Fluorescence of all Lamponite hydrogel samples
  '''Figure 3. Fluorescence of all Lamponite hydrogel samples'''
Figure 4. Fluorescence of all hydrogel samples
<br>
[[Image:Fluorescence of Rhodamine 6G collected after pressure testing(bent pipette) on hydrogels with Lamponite clay.png]]
  '''Figure 4. Fluorescence of all hydrogel samples'''
<br>
<br>
[[Image:Bent pipette pressure testing.png]]
[[Image:Bent pipette pressure testing.png]]

Latest revision as of 22:30, 26 September 2017

Project name Main project page
Previous entry      Next entry

Objectives

  1. Perform pressure tests on all prepared hydrogels using a bent pipette.
  2. Run fluorescence on the samples obtained from the pressure tests.


Pressure tests

  • Pressure tests were performed on all hydrogels prepared with Rhodamine 6G added.
  • After the sheer pressure test conducted on 2013/02/22, it was determined that a bent pipette and an unmodified pipette would be used to conduct the pressure tests. Each hydrogel will have at least two pressure tests conducted with the hydrogel: one with a bent pipette and the other with an unmodified pipette.
  • All pressure tests were conducted following the general protocol described on 2013/02/22.


Table 1. Pressure testing information for hydrogels using a bent pipette

Sample Order PVOH vs. Clay Ratio PVOH Type Clay Selection Amount of Hydrogel Used (g)
1 90:10 146K 110% CEC NaMT w/ DMHXLBR 0.1084
2 90:10 130K NaMT 0.1044
3 50:50 146K 110% CEC NaMT 0.1092
4 90:10 130K 110% CEC Laponite 0.1050
5 50:50 130K NaMT 0.1050
6 90:10 130K Laponite 0.1015
7 50:50 146K 110% CEC Laponite 0.1080
8 50:50 130K Laponite 0.1036
9 90:10 130K 110% CEC NaMT 0.1011
10 50:50 130K 110% CEC Laponite 0.1036
11 90:10 130K 110% CEC NaMT 0.1011
12 90:10 146K Laponite 0.1026
13 50:50 130K 50% CEC NaMT Bu3HdP+ 0.1052
14 50:50 146K Laponite 0.1045
15 90:10 130K 50% CEC NaMT Bu3HdP+ 0.1145


 Figure 1. Image of bent pipette used for pressure testing



 Figure 2. Fluorescence of all NaMT hydrogel ssmples



 Figure 3. Fluorescence of all Lamponite hydrogel samples


 Figure 4. Fluorescence of all hydrogel samples



  • Correction: The x-axis should be labeled wavelength(nm). The image will be corrected.