User:Moira M. Esson/Notebook/CHEM-581/2013/04/03: Difference between revisions
Line 39: | Line 39: | ||
'''Spectra''' | '''Spectra''' | ||
<br> | <br> | ||
Figure 1. Diffusion Testing of Rhodamine 6G in microspheres prepared with 90:10 ratio of PVA MW 146,000: 50% CEC NaMT | Figure 1. Diffusion Testing of Rhodamine 6G in microspheres prepared with 90:10 ratio of PVA MW 146,000-186,000: 50% CEC NaMT | ||
<br> | <br> | ||
[[Image:90 pva 146 50NaMT micros diffusion.jpg]] | [[Image:90 pva 146 50NaMT micros diffusion.jpg]] | ||
Line 45: | Line 45: | ||
*Fluorescence intensity maximum is 6.985. | *Fluorescence intensity maximum is 6.985. | ||
<br> | <br> | ||
Figure 2. Diffusion Testing of Rhodamine 6G in microspheres prepared with 90:10 ratio of PVA MW 146,000: 110% Laponite | Figure 2. Diffusion Testing of Rhodamine 6G in microspheres prepared with 90:10 ratio of PVA MW 146,000-186,000: 110% Laponite | ||
<br> | <br> | ||
[[Image:90 PVA 146 110LP micros diff.jpg]] | [[Image:90 PVA 146 110LP micros diff.jpg]] | ||
Line 51: | Line 51: | ||
*Fluorescence intensity maximum is 5.109. | *Fluorescence intensity maximum is 5.109. | ||
<br> | <br> | ||
Figure 3. Diffusion Testing of Rhodamine 6G in microspheres prepared with a 90:10 ratio PVA 146,000:NaMT | Figure 3. Diffusion Testing of Rhodamine 6G in microspheres prepared with a 90:10 ratio PVA 146,000-186,000: NaMT | ||
<br> | <br> | ||
[[Image:90 PVA 146 NaMT micros diff test.png]] | [[Image:90 PVA 146 NaMT micros diff test.png]] | ||
<br> | <br> | ||
*Fluorescence intensity maximum is 26.734 | *Fluorescence intensity maximum is 26.734 | ||
<br> | |||
Figure 4. Diffusion Testing of Rhodamine 6G in microspheres prepared with a 50:50 ratio PVA 146,000-186,000: NaMT | |||
<br> | |||
[[Image:50 PVA 146 NaMT micros diff.png]] | |||
*Fluorescence intensity maximum is | |||
Revision as of 13:57, 6 April 2013
Project name | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
Objectives
DecantingThe general protocol described on 2013/03/01 was followed.
DSC