User:Paul Rothenberg/Notebook/CHEM 571 Fall 2014/2014/09/17: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(fix raw html notebook nav)
 
(3 intermediate revisions by one other user not shown)
Line 2: Line 2:
|-
|-
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #EEE"|[[Image:owwnotebook_icon.png|128px]]<span style="font-size:22px;"> Project name</span>
|style="background-color: #F2F2F2" align="center"|<html><img src="/images/9/94/Report.png" border="0" /></html> [[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>[[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]]<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>}}
|style="background-color: #F2F2F2" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;}}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}}
|-
|-
| colspan="2"|
| colspan="2"|
Line 9: Line 9:


Yesterday and today, we ran pH and conductivity calibrations for 50 mM NaCl and 50 mM Glycine buffers (pH 3.5, 0.4 mL 1M HCl used). A 2x, 5z, 10x, 20x, 50x, 100x, 200x, and 500x dilution of each was prepared for use.  
Yesterday and today, we ran pH and conductivity calibrations for 50 mM NaCl and 50 mM Glycine buffers (pH 3.5, 0.4 mL 1M HCl used). A 2x, 5z, 10x, 20x, 50x, 100x, 200x, and 500x dilution of each was prepared for use.  
[[Image:NaCl_Glycine_Tables_17_Sept.png|500px]]


The results are as follows:
The results are as follows:
Line 14: Line 16:
'''NaCl'''
'''NaCl'''


[[Image:NaCl_Conductivity_17_Sept.png]]
[[Image:NaCl_Conductivity_17_Sept.png|500px]]


[[Image:NaCl_Log_Conc_pH_17_Sept.png]]
[[Image:NaCl_Log_Conc_pH_17_Sept.png|500px]]


[[Image:NaCl_pH_17_Sept.png]]
[[Image:NaCl_pH_17_Sept.png|500px]]


'''Glycine'''
'''Glycine'''


[[Image:Glycine_Conductivity_17_Sept.png]]
[[Image:Glycine_Conductivity_17_Sept.png|500px]]
 
[[Image:Glycine_Log_Conc_pH_17_Sept.png|500px]]
 
[[Image:Glycine_pH_17_Sept.png|500px]]
 
==Lysozyme 1g/L Data==


[[Image:Glycine_Log_Conc_pH_17_Sept.png]]
pH and conductivity were taken for the stock solution and for a 1 in 6 dilution.  


[[Image:Glycine_pH_17_Sept.png]]
#Stock
##pH - 5.700
##Conductivity - 144.6 µS/cm
#1 in 6 Dilution
##pH - 6.123
##Conductivity - 24.14 µS/cm


==Dialysis==
==Dialysis==

Latest revision as of 00:18, 27 September 2017

Project name Main project page
Previous entry      Next entry

pH and Conductivity Calibration of NaCl and Glycine Buffers

Yesterday and today, we ran pH and conductivity calibrations for 50 mM NaCl and 50 mM Glycine buffers (pH 3.5, 0.4 mL 1M HCl used). A 2x, 5z, 10x, 20x, 50x, 100x, 200x, and 500x dilution of each was prepared for use.

The results are as follows:

NaCl

Glycine

Lysozyme 1g/L Data

pH and conductivity were taken for the stock solution and for a 1 in 6 dilution.

  1. Stock
    1. pH - 5.700
    2. Conductivity - 144.6 µS/cm
  2. 1 in 6 Dilution
    1. pH - 6.123
    2. Conductivity - 24.14 µS/cm

Dialysis

We used the two buffers to run dialysis of 1 g/L lysozyme. We used 3500 and 25k MW dialysis tubing. The 3500 was used for NaCl, Glycine, and H2O, and colloid solution (made on 26 August). These were left overnight to today.