User:Samiye Yaman/Notebook/Lab 571/2011/11/09: Difference between revisions

From OpenWetWare
< User:Samiye Yaman‎ | Notebook‎ | Lab 571‎ | 2011‎ | 11
Jump to navigationJump to search
Line 17: Line 17:
1)Synthesizing gold nanoparticles.
1)Synthesizing gold nanoparticles.


-Big Epi Test tube 2A with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. (BIG/ SLOW/ WITH AIR)
-Big Epi Test tube 2A with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and immediately took it out of the heat block at the end. (BIG/ FAST / WITH AIR)


-Small Epi Test tube 2B with 100ul of BSA, 4000ul of water and 100ulof chloroauric acid.The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. (SMALL/ FAST/ WITHOUT AIR)
-Small Epi Test tube 2B with 100ul of BSA, 400ul of water and 100ulof chloroauric acid.The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. (SMALL/ FAST/ WITHOUT AIR)


-Big Epi test tube 2C with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/ SLOW/ WITH AIR)
-Big Epi test tube 2C with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/ SLOW/ WITH AIR)


-Small Epi Test tube 2D with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and took it out of the heat block by decreasing the temperature.(SMALL/ SLOW/ WITHOUT AIR)
-Small Epi Test tube 2D with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and took it out of the heat block by decreasing the temperature.(SMALL/ SLOW/ WITHOUT AIR)


-Big Epi Test tube 2E with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. Every 30min, the lid of the epi test tube was open.(BIG/ FAST/ WITH AIR/ OPEN LID)
-Big Epi Test tube 2E with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and immediately took it out of the heat block at the end. Every 30min, the lid of the epi test tube was open.(BIG/ FAST/ WITH AIR/ OPEN LID)


-Big Epi Test tube 2F with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end.(BIG/ FAST/ WITH AIR)
-Big Epi Test tube 2F with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and immediately took it out of the heat block at the end.(BIG/ FAST/ WITH AIR/400ul WATER)


-Big Epi Test tube 2G with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/ SLOW/ WITH AIR)
-Big Epi Test tube 2G with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/ SLOW/ WITH AIR/400ul WATER)


==Data==
==Data==

Revision as of 11:43, 9 November 2011

Biomaterials Design Lab <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>

Entry title

Objective

Description

Synthesizing Gold nanoparticles.

1)Synthesizing gold nanoparticles.

-Big Epi Test tube 2A with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and immediately took it out of the heat block at the end. (BIG/ FAST / WITH AIR)

-Small Epi Test tube 2B with 100ul of BSA, 400ul of water and 100ulof chloroauric acid.The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. (SMALL/ FAST/ WITHOUT AIR)

-Big Epi test tube 2C with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/ SLOW/ WITH AIR)

-Small Epi Test tube 2D with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and took it out of the heat block by decreasing the temperature.(SMALL/ SLOW/ WITHOUT AIR)

-Big Epi Test tube 2E with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and immediately took it out of the heat block at the end. Every 30min, the lid of the epi test tube was open.(BIG/ FAST/ WITH AIR/ OPEN LID)

-Big Epi Test tube 2F with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and immediately took it out of the heat block at the end.(BIG/ FAST/ WITH AIR/400ul WATER)

-Big Epi Test tube 2G with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 80 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/ SLOW/ WITH AIR/400ul WATER)

Data

  • Add data and results here...

Notes

This area is for any observations or conclusions that you would like to note.


Use categories like tags. Change the "Course" category to the one corresponding to your course. The "Miscellaneous" tag can be used for particular experiments, as instructed by your professor. Please be sure to change or delete this tag as required so that the categories remain well organized.