User:Samiye Yaman/Notebook/Lab 571/2011/11/09
Biomaterials Design Lab | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
Entry titleObjectiveDescriptionSynthesizing Gold nanoparticles. 1)Synthesizing gold nanoparticles. -Big Epi Test tube 2A with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. (BIG/SLOW/WITH AIR) -Small Epi Test tube 2B with 100ul of BSA, 4000ul of water and 100ulof chloroauric acid.The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. (SMALL/FAST/WITHOUT AIR) -Big Epi test tube 2C with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/SLOW/WITH AIR) -Small Epi Test tube 2D with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and took it out of the heat block by decreasing the temperature.(SMALL/SLOW/WITHOUT AIR) -Big Epi Test tube 2E with 100 ul of BSA, 800ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end. Every 30min, the lid of the epi test tube was open.(BIG/FAST/WITH AIR/OPEN LID) -Big Epi Test tube 2F with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and immediately took it out of the heat block at the end.(BIG/FAST/WITH AIR) -Big Epi Test tube 2G with 100ul of BSA, 400ul of water and 100ul of chloroauric acid.(with this order) was prepared. The test tube was placed in to the heat block which was at 75 degree celcius and took it out of the heat block by decreasing the temperature.(BIG/SLOW/WITH AIR) Data
NotesThis area is for any observations or conclusions that you would like to note.
|