User:Sarah Labianca/Notebook/Smyth Lab/2012/02/23

From OpenWetWare

< User:Sarah Labianca | Notebook | Smyth Lab | 2012 | 02(Difference between revisions)
Jump to: navigation, search
(Autocreate 2012/02/23 Entry for User:Sarah_Labianca/Notebook/Smyth_Lab)
Current revision (11:21, 24 February 2012) (view source)
m
 
(2 intermediate revisions not shown.)
Line 1: Line 1:
 +
[[Category:SL-Particle Surface Interactions]]
{|{{table}} width="800"
{|{{table}} width="800"
|-
|-
Line 6: Line 7:
| colspan="2"|
| colspan="2"|
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
<!-- ##### DO NOT edit above this line unless you know what you are doing. ##### -->
-
==Entry title==
+
The Chatillon TCD did not work very well in measuring the force generated by the pendulum. We figured out why -- it is meant to measure tension and compression, not impulses. It does not read in measurements at a high enough frequency to measure the impact force of our pendulum.
-
* Insert content here...
+
It also seems to be that FSR's may not have a high enough frequency of measurement as well. We will still connect it to an ADC, and try it out to see what happens.  
 +
Alternate solutions include using piezoelectric sensors or an accelerometer -- more on that later.

Current revision

Project name Main project page
Previous entry      Next entry

The Chatillon TCD did not work very well in measuring the force generated by the pendulum. We figured out why -- it is meant to measure tension and compression, not impulses. It does not read in measurements at a high enough frequency to measure the impact force of our pendulum. It also seems to be that FSR's may not have a high enough frequency of measurement as well. We will still connect it to an ADC, and try it out to see what happens. Alternate solutions include using piezoelectric sensors or an accelerometer -- more on that later.



Personal tools