User:Tara K. Luckau/Notebook/Team ConGen/2011/01/14: Difference between revisions

From OpenWetWare
Jump to navigationJump to search
(One intermediate revision by the same user not shown)
Line 44: Line 44:
The largest difference between the two reactions was Taq - 10-fold difference
The largest difference between the two reactions was Taq - 10-fold difference


In the interest of cost, try to pull this down to 1 Unit/reaction (0.2µL)
* In the interest of cost, try to pull this down to 1 Unit/reaction (0.2µL)
* Also re-calculate for 10µL reaction volume
* Find annealing temperatures (touchdowns are poopy)
 
 
 
==PCR decrease Taq==
* [[Image:20110114_PCROpt_Touchdown.jpg|900 px]]





Revision as of 16:24, 14 January 2011

Tara's Lab Notebook <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>


Gel Lance conditions

Success!!!



  • Scun2 Primer - expecting bands ~150bp
    • Scun sample - band at 130bp
    • Scoc sample - band at 75bp


  • Scun22 Primer - expecting bands at ~450bp
    • Scun sample - multiple bands; but there is one prominent band in one of the replicates at 450bp
    • Scoc sample - multiple bands; but prominent band in all three replicates at 450bp


Differences between Lance conditions and previous trials

10January2011 (fail) 13January2011 (worked)
Buffer / MgCl2 1.5 µL 1 µL
Primers 0.1 µL each 0.25 µL each
Taq 0.05 µL (0.25 Units) 0.5 µL (2.5 Units)

The largest difference between the two reactions was Taq - 10-fold difference

  • In the interest of cost, try to pull this down to 1 Unit/reaction (0.2µL)
  • Also re-calculate for 10µL reaction volume
  • Find annealing temperatures (touchdowns are poopy)


PCR decrease Taq