====MP1a====
=====Acos3=====
* 23 July 2012: no changes needed
* this time:
: still fine, though seems to decrease with increasing Acos5 as well as Ai5071
=====Acos5=====
* 23 July 2012: too high
* this time:
: 0.04 = too low
: 0.06 = inconclusive (failures)
: 0.08 = too high
=====Ai5013=====
* 23 July 2012: too low
* this time:
: second peak never got above 250, regardless of concentration
: however, in Acos5 assay, noticed second peak reached 400 intensity as Acos5 decreased
=====Ai5043=====
* 23 July 2012: did not amplify
* this time: did not amplify
: remove from multiplex
=====Ai5071=====
* 23 July 2012: too low
* this time:
: best at 0.24, 0.28, 0.32 (200-300 intensity only)
====MP1b====
=====Ai5033=====
* 23 July 2012: no changes needed
* this time:
: still fine (no amp for any markers in Ai5057 assay)
=====Ai5035=====
* 23 July 2012: no changes needed
* this time:
: a bit low in Ai5062 assay (no amp for any markers in Ai5057 assay)
=====Ai5037=====
* 23 July 2012: no changes needed
* this time:
: still fine (no amp for any markers in Ai5057 assay)
=====Ai5057=====
* 23 July 2012: did not amplify
* this time: did not amplify
: remove from multiplex
=====Ai5062=====
* 23 July 2012: too low
* this time:
: best at 0.48 (400 & 6000 intensity)





Revision as of 15:49, 27 November 2012

Tara's Lab Notebook <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page
<html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html>


CNHY MP1a/b Optimization

  • optimize for marker peak height - vary each primer (based on results from 23 July 2012)
  • CNHY MP1a: increase Ai5013, Ai5043, Ai5071
  • CNHY MP1a: decrease Acos5
  • CNHY MP1b: increase Ai5057, Ai5062

Frag Results

  • UAGC submission# YFPQ


MP1a

Acos3
  • 23 July 2012: no changes needed
  • this time:
still fine, though seems to decrease with increasing Acos5 as well as Ai5071
Acos5
  • 23 July 2012: too high
  • this time:
0.04 = too low
0.06 = inconclusive (failures)
0.08 = too high
Ai5013
  • 23 July 2012: too low
  • this time:
second peak never got above 250, regardless of concentration
however, in Acos5 assay, noticed second peak reached 400 intensity as Acos5 decreased
Ai5043
  • 23 July 2012: did not amplify
  • this time: did not amplify
remove from multiplex
Ai5071
  • 23 July 2012: too low
  • this time:
best at 0.24, 0.28, 0.32 (200-300 intensity only)


MP1b

Ai5033
  • 23 July 2012: no changes needed
  • this time:
still fine (no amp for any markers in Ai5057 assay)
Ai5035
  • 23 July 2012: no changes needed
  • this time:
a bit low in Ai5062 assay (no amp for any markers in Ai5057 assay)
Ai5037
  • 23 July 2012: no changes needed
  • this time:
still fine (no amp for any markers in Ai5057 assay)
Ai5057
  • 23 July 2012: did not amplify
  • this time: did not amplify
remove from multiplex
Ai5062
  • 23 July 2012: too low
  • this time:
best at 0.48 (400 & 6000 intensity)