|style="background-color: #FFCC00"|<br>[[Image:Hayneslab3.gif|200px|center]][[Image:Asu logo 3.gif|200px|center]]<span style="font-size:22px;"><br></span> | |style="background-color: #FFCC00"|<br>[[Image:Hayneslab3.gif|200px|center]][[Image:Asu logo 3.gif|200px|center]]<span style="font-size:22px;"><br></span> | ||
|style="background-color: #800000" align="center"| | |style="background-color: #800000" align="center"|[[File:Report.png|frameless|link={{#sub:{{FULLPAGENAME}}|0|-11}}]][[{{#sub:{{FULLPAGENAME}}|0|-11}}|Main project page]]<br />{{#if:{{#lnpreventry:{{FULLPAGENAME}}}}|[[File:Resultset_previous.png|frameless|link={{#lnpreventry:{{FULLPAGENAME}}}}]][[{{#lnpreventry:{{FULLPAGENAME}}}}{{!}}Previous entry]] }}{{#if:{{#lnnextentry:{{FULLPAGENAME}}}}|[[{{#lnnextentry:{{FULLPAGENAME}}}}{{!}}Next entry]][[File:Resultset_next.png|frameless|link={{#lnnextentry:{{FULLPAGENAME}}}}]]}} | ||
|- | |- | ||
| colspan="2"| | | colspan="2"| | ||
Line 21: | Line 21: | ||
| PstI|| 1.0 μL | | PstI|| 1.0 μL | ||
|- | |- | ||
| Green 10x FastDigest buffer || | | Green 10x FastDigest buffer || 0μL | ||
|- | |- | ||
| dH<sub>2</sub>O || | | dH<sub>2</sub>O || 18 μL | ||
|- | |- | ||
| || 30 μL --> 37°C/ ~10 min. | | || 30 μL --> 37°C/ ~10 min. | ||
Line 74: | Line 74: | ||
[[Image:hiddendragonsofthetemple.jpg|250px|CMV PEG/MgCl<sub>2</sub> Precipitation 9/26/2013]] | [[Image:hiddendragonsofthetemple.jpg|250px|CMV PEG/MgCl<sub>2</sub> Precipitation 9/26/2013]] | ||
Higher molecular mass DNA precipitates at lower PEG concentrations than lower molecular mass DNA, according to [http://www.ncbi.nlm.nih.gov/pmc/articles/PMC342844/ Lis and Schleif 1975, NAR]. I kept DNA from the supernatant and discarded the precipitated DNA. | |||
Therefore, I should see larger bands at 2% PEG and smaller bands at 15% PEG. | |||
Latest revision as of 23:23, 26 September 2017
Main project page Previous entry Next entry | |||||||||||||||||||||||||||||||||||||||||||||
September 26, 2013Restriction Digest
PEG/MgCl2 Precipitation
DNA Clean & Concentrator
Gel Electrophoresis
Higher molecular mass DNA precipitates at lower PEG concentrations than lower molecular mass DNA, according to Lis and Schleif 1975, NAR. I kept DNA from the supernatant and discarded the precipitated DNA. Therefore, I should see larger bands at 2% PEG and smaller bands at 15% PEG.
|