IGEM:MIT/2007/Notebook/2007-6-11: Difference between revisions
From OpenWetWare
Jump to navigationJump to search
Line 31: | Line 31: | ||
*Autoclaved water is sterile | *Autoclaved water is sterile | ||
=== | ===Growing up bacterial colonies from plates=== | ||
*Must pick up colonies to grow – inoculation in test tubes – grow over night in media | *Must pick up colonies to grow – inoculation in test tubes – grow over night in media | ||
*Put antibiotic in media – all non-plasmid containing bacteria will die (selective amplification) | *Put antibiotic in media – all non-plasmid containing bacteria will die (selective amplification) |
Revision as of 07:22, 12 June 2007
Day Outline
- 9am: Meet at 68-577
- Morning: Primer design (BE 109 protocol)
- Afternoon: Topic/Paper research
LAB WORK
please fill in details
- added Amp to 500ml LB
- innoculate 5ml LB/Amp with bact. colonies (EGFP and NNX)
- made 1 liter 1% agarose solution
....................
Enjoy the tips and protocols below -- and add any suggestions if you'd like! --SK
General Lab Do s and Don’t s
- Pipettes: don’t use over maximum amount/under minimum amount; don’t contaminate pipette by using higher than necessary
- Different pipette tips exist – look at the labels [filters, sizes, etc.]
- When pipetting up, get used to knowing where fluids should end
- Pipetting fluid – make sure suck up full volume (don’t take out of container too quickly); don’t touch bottom of container; push pipette down first and then pull up (don’t make bubbles)
- Dispensing – go down both notches
- Sucking up – go down one notch
- Resuspension – mixing by continually sucking up and down (NO BUBBLES)
- Look at different numbers on pipettes
- If desired, practice on cup of water!
- KNOW HOW MUCH ONE MICROLITER IS (for PCR)
- Put all enzymes inside cooling blocks next to freezers to avoid denaturation [such as Amp for LB]
- Stockroom is also used for carcinogens – DNA staining chemical – don’t touch anything!
- Before work: spray ethanol on bench and gloves; Kimwipe (not on open flame!)
- Be as sterile as possible! LB is made in building 68 – can pick up more
- Automatic Bunsen burners – continuous or sensor
- Autoclaved water is sterile
Growing up bacterial colonies from plates
- Must pick up colonies to grow – inoculation in test tubes – grow over night in media
- Put antibiotic in media – all non-plasmid containing bacteria will die (selective amplification)
- Antibiotic into LB: 500 LB needs 500 microliters of Amp
- Use Bunsen burner, gloves
- 500 microliters of Amp into LB flask after warming near lip of LB bottle
- Discard tips into small buckets on top of bench; dump into red sharps container at end of day
- Mark remaining Amp volume with marker
- Freezer for iGEM: white, shared for now; later will have freestanding under bench
- Use lab tape to re-label and update flasks/containers with substance name, iGEM, date and your initials
- Plates go into metal container [opposite bench]
- Keep LB as sterile as possible by opening only once – pour needed amount into sterile blue screw cap bottles and label with name, iGEM, date and initials
- Transferring LB to blue screw cap – lid of LB down on bench; put LB bottle over Bunsen burner
- Temporary fridge space in front of bench
- Bacteria with two different types of vectors on streaked plates – make far enough apart to form colony
- Make sure automatic pipetter is charging; don’t suck up into device
- 70% ethanol mix: to 400 with ethanol; rest with distilled water
- Glass test tubes of two plasmids – label with name of plasmid and all other relevant details – both cap and tube
- Use 10 mL pipette (glass) and automatic pipette (upper button is up) – 5 mL of LB Amp into each tube (inoculation of 5 mL)
- Don’t open glass tube cap until necessary
- Glass pipettes into liquid-containing plastic waste jar
- Flame the metal loop
- Use two fingers to lift cap of glass tube
- Flame top of tube before and after touching bacterial colony
- Let metal loop cool to temperature of gel by stabbing loop on agar with no colonies
- Touch metal loop lightly to one colony and touch to the top of LB broth; mix in broth
- A tip: Distinguish before/after inoculation tubes by placing in different rows of the test tube holder
- Put the test tubes into incubator in warm (37ºC) room – make sure you switch off the rotating device first, put in all tubes, and then TURN BACK ON!
- Note the time that incubation starts (for today, 16.29)
- If something is growing in culture that should not be there, dump it out after pouring bleach inside
- Clean up: Parafilm all containers
- LB and Amp go in fridge – must warm up before using next time
Making Plates
- 1% agarose gel
- Stock agarose solution (for gels)
- 1 Liter flask
- Anything with foil on it is sterile – LB flask does not have to be sterile, since it will be heated anyway
- Label 1% agarose, iGEM, TAE buffer, date
- 1% is weight per volume
- 1 mg/mL = 100% [water]
- 10 mg/mL = 1%
- Get agarose and weigh out 10 mg using boat or paper
- Pour agarose into large flask
- Clean up weighing area (brush)
- Get 1 L graduated cylinder (not sterile) and fill with 1x TAE buffer
- Pour in half the TAE buffer from the cylinder into the flask and put in microwave
- Wait until bubbling and mix/stir – continue pouring in more buffer until clear
- Store in 55ºC box with cap halfway on (no explosions)
POSSIBLE IDEAS
Leading Concepts
Illuminate in Dark- Maybe
Sticky Bacteria- lacking application but maybe
Requiring Further Research
Synthesizing Vitamins – Further research TTP JCH
Extreme environment – yes LBH SK
Chitin Bandaid- More info AWL
FOOD? Spoilage/Binding to plastic – yes AGK