==Procedures== | ==Procedures== | ||
Part 1: Preparation of 1mL of 2.98μM ethane thiol | '''Part 1: Preparation of 1mL of 2.98μM ethane thiol''' | ||
WARNING: ethanethiol is very volatile. Handle under the hood only wearing PPE. | |||
* original concentrationof AuNP = 19.4nM | * original concentrationof AuNP = 19.4nM |
Revision as of 07:49, 9 April 2013
Project name | <html><img src="/images/9/94/Report.png" border="0" /></html> Main project page <html><img src="/images/c/c3/Resultset_previous.png" border="0" /></html>Previous entry<html> </html>Next entry<html><img src="/images/5/5c/Resultset_next.png" border="0" /></html> |
Objectives
ProceduresPart 1: Preparation of 1mL of 2.98μM ethane thiol WARNING: ethanethiol is very volatile. Handle under the hood only wearing PPE.
1) Calculating concentration of ethanethiol 0.839g/mL x 0.025mL = 0.020975g 0.020975g/(62.13 g/mol) = 3.376 x 10-4 mol 3.376 x 10-4 mol/1mL x (1000mL/1L) = 0.34M = 340mM 340mM (x) = (30mM)(1mL) x = 0.088mL = 88μL in 912μL H2O 30mM (x) = 3mM (1mL) x = 100μL in 900μL 3mM(x) = 298μM (1mL) x = 99μL in 901μL to obtain 298μM ethanethiol 2) Reacting AuNP with ethanethiol
Part 2: Measure absorbance/fluorescence of AuNP-MB Part 3: Measure absorbance/fluorescence of AuNP-ThT
|