Wittrup: Dishwashing
From OpenWetWare
Glass bottles, glass flasks
- wash in dishwasher (Cycle 1: Glassware)
- autoclave (Cycle 5: 30 min sterilization, 30 min dry)
- place on shelves in tissue culture support room (76-286)
Centrifuge bottles, Tunair flasks
- wash in dishwasher (Cycle 6: Plastics)
- place on shelves in tissue culture support room (76-286)
- NOTE: plastic bottles and flasks to be autoclaved as needed by user
do not wash filters in Tunair flask caps
Spatulas, stir bars
- wash in dishwasher (Cycle 1: Glassware)
- place in containers on table in incubator / shaker room (76-284)
Pipet tips, microcentrifuge tubes, culture tubes
- autoclave (Cycle 5: 30 min sterilization, 30 min dry)
- place on shelves in dishwasher / autoclave room (76-292)
- place some on table in main lab (76-291)
Pasteur pipettes
- autoclave (Cycle 5: 30 min sterilization, 30 min dry)
- place on shelves in tissue culture room (76-285)
Biohazard Waste
- autoclave (Cycle 1: 90 min sterilization)
- allowed to cool, then place each bag into a black plastic bag, secure, and set in hallway
- NOTE: just before autoclaving, open up waste bags to allow in steam during cycle
Biohazard Sharps
- transport all full sharps bins to the accumulation room
- bring empty bins from the accumulation area to the tissue culture support room
- NOTE: empty bins are stored in the tissue culture support room (76-286)
full bins are stored in the incubator / shaker room (76-284) the general accumulation area is room 76-268 (key on lab whiteboard)
Gel Buffers
- TAE, MES, MOPS, and transfer buffers are in room 76-287
- ensure all buffers are above refill line throughout the week
By the end of the day on Friday...
- unwashed glassware < 1 load
- biohazard waste < 2 bags